6030 W HAROLD GATTY DRIVE
SALT LAKE CITY, UT 84116

Stiletto™ Extended Dwell Catheter
Enhanced Midline Catheter Performance with Peripheral IV Ease of Insertion
OVERVIEW
Guidewire-free Insertion Using a
Proprietary Catheter Advancement Mechanism
Insertion is as easy as "Stick-Flick-Click"
The Guidewire-free approach allows for over-the-needle access that is as easy as inserting a peripheral IV

FEATURES AND BENEFITS
The structural support provided by the sheathing cannula during insertion allows the catheter to be softer than the market leading competitive product, potentially improving biocompatibility and increasing dwell times.
Catheter is constructed from body-softening polyurethane.


The reinforced catheter tip helps to prevent tip collapse during aspiration, potentially minimizing the risk of hemolysis or loss of catheter patency.
Stiletto’s catheter diameter to needle diameter ratio is larger than the leading market competitor.
Having a smaller needle relative to the catheter diameter potentially reduces the incidence of:
-
Infiltration/extravasation through improved sealing between the catheter and the vein wall
-
Phlebitis and thrombus though reduced vessel and tissue trauma

Bright Needle Tip
-
Echogenic needle tip aids in ease of vascular access using ultrasonography.


Clear Blood Flashback
-
Notches in the tip of the needle and sheathing cannula allow for rapid visualization of blood return along the length of the catheter immediately following venipuncture.
Easy to see Using Fluoroscopy
-
Radiopaque stripes run the length of the catheter, allowing for clear radiographic visualization without obstructing visualization of blood flash upon venipuncture.

Upon full deployment of the catheter into the vessel, the needle tip is automatically sheathed inside the sheathing cannula, reducing the risk of needlestick injuries to caregivers and patients.

3 Primary Steps:
Designed to allow for closest grip to hub for maximum control.
Uses similar deployment movement as IV catheters.

This catheter allows for power injection of contrast media.

-
18G: 7mL/sec
-
20G: 5mL/sec
⚠ Do not exceed the maximum flow rate for each configuration and maximum pressure injection settings of 325 psi (2241 kpa) at 37°.
MODEL
The Stiletto Extended Dwell Catheter is Made in the Following Gauges and Lengths
Model: PIP200000
Catheter Length: 8cm
Needle Size: 20 Gauge

Model: PIP210100
Catheter Length: 10cm
Needle Size: 18 Gauge

Model: PIP200100
Catheter Length: 10cm
Needle Size: 20 Gauge

Model: PIP210200
Catheter Length: 12cm
Needle Size: 18 Gauge

RESOURCES
Indications for Use